Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Choose a sub category:
BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1 2 3 ... 8
Southwire 14BK-STRX500 Stranded Single Building Wire Southwire 14GRN-STRX500 Stranded Single Building Wire Southwire 14BK-SOLX500 Solid Single Building Wire
Southwire? Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 109 mil, 600 V, 15 A, Operating Temperature: 90 deg C Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? Building Wire, Type THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Black, 600 V, 15 A, Operating Temperature: 90 deg C
Southwire 14WHT-SOLX500 Solid Single Building Wire Southwire 14RED-SOLX500 Solid Single Building Wire Southwire 14GRN-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Red, 600 V, 15 A, Operating Temperature: 90 deg C Southwire? Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Green, 600 V, 15 A, Operating Temperature: 90 deg C
Southwire 14WHT-STRX500 Stranded Single Building Wire Southwire 14RED-STRX500 Stranded Single Building Wire Southwire 14BLUE-STRX500 Stranded Single Building Wire
Southwire? Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, 600 V, 15 A, Operating Temperature: 90 deg C Southwire? Building Wire, Type THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Red, Sheath Diameter: 15 mil, 600 V, 15 A, Operating Temperature: 90 deg C Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 14BLUE-SOLX500 Solid Single Building Wire Southwire 14YEL-SOLX500 Building Wire Southwire 12YEL-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 12GRN-STRX500 Stranded Single Building Wire Southwire 12BK-SOLX500 Solid Single Building Wire Southwire 12WHT-SOLX500 Solid Single Building Wire
Southwire? Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Green, 600 V, 20 A, Operating Temperature: 90 deg C Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: White, 600 V, 20 A, Operating Temperature: 90 deg C
Southwire 12RED-SOLX500 Tungsten Quartz Single Ended Building Wire Southwire 12BLU-SOLX500 Solid Single Building Wire Southwire 12GRN-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? Type THHN Building Wire, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Green, 600 V, 20 A, Operating Temperature: 90 deg C
Southwire 12BK-STRX500 Stranded Single Building Wire Southwire 12WHT-STRX500 Single Ended Building Wire Southwire 12RED-STRX500 Stranded Single Building Wire
Southwire? Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, 600 V, 20 A, Operating Temperature: 90 deg C Southwire? Type THHN Building Wire, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 128 mil, 600 V, 20 A, Operating Temperature: 90 deg C Southwire? Building Wire, Type THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Red, 600 V, 20 A, Operating Temperature: 90 deg C
Southwire 12BLU-STRX500 Stranded Single Building Wire Southwire 12YEL-STRX500 Stranded Single Building Wire Coleman 94605M418 Type CL-2 Speaker Cable
Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Parallel wire, power limited circuit cable, -20 to 105 deg C. Used for stereos and hi-fi systems, home theater sound systems, lamps and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. 250 ft per roll.
Southwire 10WHT-STRX500 Stranded Single Building Wire Southwire 10GRN-STRX500 Stranded Single Building Wire Southwire 10BK-SOLX500 Solid Single Building Wire
Southwire? Building Wire, THHN, Wire Size: 10 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 161 mil, 600 V, 30 A, Operating Temperature: 90 deg C Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 10WHT-SOLX500 Solid Single Building Wire Southwire 10RED-SOLX500 Solid Single Building Wire Southwire 10GRN-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN copper conductors are designed to be installed without application of a pulling lubricant.
   
 
1 2 3 ... 8